Search
Search Criteria
Products meeting the search criteria
FM1020 Load Cell (FM1020)
Used in PLC Applications, Precision Balance, Analytical balance, low capacity scale
L6E3 (L6E3)
Aluminum-alloy IP65 single-point load cell.
Adhesive sealed.
Colorless anodized.
Suitable for single and double-load cells structured platform scale.
Model: L6F3 Class: C3
Resistance:
Input - 406Ω ± 6Ω Output - 350Ω ± 3.5Ω
Brand: Zemic
Mfg: Zemic Europe. (B.V Netherland)
Origin: Assembled in China
HM9B Loadcell (Analog HM9B)
Short Description:
Nickel-plated alloy steel IP68 dual shear beam
High accuracy
Suitable for trucks, tracks, hoppers and other electronic weighing devices
Current calibrated (sc-option)
Manufacturer: Zemic Europe. (B.V Netherland)
Origin: Assembled in China
Available Capacity:
Capacity Accuracy Full Article Description 10 Ton C3 HM9B-C3-10t-12B-2-FH 20 Ton C3 HM9B-C3-20t-12B-2-FH 25 Ton C3 HM9B-C3-25t-20B(-SC) -2-FH 30 Ton C3 HM9B-C3-30t-20B(-SC) -2-FH 40 Ton C3 HM9B-C3-40t-16B-2-FH 50 Ton C3 HM9B-C3-50t-16B-2-FH
Technical Specifications HM9B
Accuracy Class OIML R60 C3 Output Sensitivity ( FS ) mV/V 2.0 ± 0.002 Maximum Capacity ( Emax ) kg 10, 20, 25 30, 40, 50 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / vmin 15000, 7500 Combined Error %FS ≤± 0.02 Creep Error (30 minutes) %FS ≤± 0.02 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.02 Zero Balance %FS ≤± 1.5 Safe Overload %FS 150 Ultimate Overload %FS 300 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 700 ± 7 Output Resistance Ω 703 ± 4 Insulation Resistance (50V) MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Load Cell Weight kg 10t: 15 20t – 40t: ~17 50t: 25 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP68 Recommended Torque on Fixation Bolts Nm 1100 ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 24
Cable diameter: Ø 5.5mm
Cable length: 16m (standard), 12m & 20m lengths also available
Cable jacket: PVC Shield not connected to the element
Wiring Instruction:
Input(Positive) - Red
Input (Negative) - Black
Output(Positive) - Green
Output(Negative) - White
Shield - Gray
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
HM9B Loadcell (Digital HM9B)
Short Description:
Nickel-plated alloy steel IP68 dual shear beam
High accuracy
Suitable for trucks, tracks, hoppers and other electronic weighing devices
Current calibrated (sc-option)
Manufacturer: Zemic Europe. (B.V Netherland)
Origin: Assembled in China
Available Capacity:
Capacity Accuracy Full Article Description 10 Ton C3 HM9B-C3-10t-12B-2-FH 20 Ton C3 HM9B-C3-20t-12B-2-FH 25 Ton C3 HM9B-C3-25t-20B(-SC) -2-FH 30 Ton C3 HM9B-C3-30t-20B(-SC) -2-FH 40 Ton C3 HM9B-C3-40t-16B-2-FH 50 Ton C3 HM9B-C3-50t-16B-2-FH
Technical Specifications HM9B
Accuracy Class OIML R60 C3 Output Sensitivity ( FS ) mV/V 2.0 ± 0.002 Maximum Capacity ( Emax ) kg 10, 20, 25 30, 40, 50 Max. Number of Load Cell Intervals nLC 3000 Ratio of min. LC Verification Interval Y = Emax / vmin 15000, 7500 Combined Error %FS ≤± 0.02 Creep Error (30 minutes) %FS ≤± 0.02 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.02 Zero Balance %FS ≤± 1.5 Safe Overload %FS 150 Ultimate Overload %FS 300 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 700 ± 7 Output Resistance Ω 703 ± 4 Insulation Resistance (50V) MΩ ≥5000 Compensated Temperature °C -10 ~ 40 Operating Temperature °C -35 ~ 65 Storage Temperature °C -40 ~ 70 Load Cell Weight kg 10t: 15 20t – 40t: ~17 50t: 25 Element Material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP68 Recommended Torque on Fixation Bolts Nm 1100 ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 24
Cable diameter: Ø 5.5mm
Cable length: 16m (standard), 12m & 20m lengths also available
Cable jacket: PVC
Shield not connected to the element
Wiring Instruction:
Input(Positive) - Red
Input (Negative) - Black
Output(Positive) - Green
Output(Negative) – White
Shield - Gray
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
- 1